Vertebral Stent Compression due to Supra-Aortic Variations: Case Report


ÖKÇESİZ İ., MEZGİTLİ E., DÖNMEZ H., KARABIYIK Ö.

GAZI MEDICAL JOURNAL, cilt.32, sa.2, ss.238-241, 2021 (ESCI) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 32 Sayı: 2
  • Basım Tarihi: 2021
  • Doi Numarası: 10.12996/gmj.2021.54
  • Dergi Adı: GAZI MEDICAL JOURNAL
  • Derginin Tarandığı İndeksler: Emerging Sources Citation Index (ESCI), Scopus, Academic Search Premier
  • Sayfa Sayıları: ss.238-241
  • Anahtar Kelimeler: variation of vertebral artery, dissection, endovascular stent treatment, ARTERY
  • Erciyes Üniversitesi Adresli: Evet

Özet

Vertebral artery variations are rare developmental anomalies. Although these variations are generally asymptomatic; it can predispose such pathologies as dissection, intracranial aneurysm. Additionally, these variations can effect on the treatment plan and endovascular / surgical approach.In our case, bilateral vertebral artery variations accompanying the abberant right subclavian artery were presented and abnormal origin and high foraminal entry variation were observed in the right vertebral artery. On the basis of this variation, symptomatic dissection was observed at the level of the foraminal segment of the right vertebral artery. A metallic stent was placed by endovascular approach, however the stent was compressed in follow-up period.Abnormal vascular origin, branching and running variations in functional vascular anatomy significantly affects the incidence of disease and treatment success.