Magnetic Rubber@Ni-Co layered double hydroxide derived from ZIF-67 template as nanostructured sorbent; application in determination of anticancer drugs in plasma samples


Riazi Bonab H., Abbas Matin A., Heidari H., SOYLAK M.

Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences, vol.1241, 2024 (SCI-Expanded) identifier identifier identifier

  • Publication Type: Article / Article
  • Volume: 1241
  • Publication Date: 2024
  • Doi Number: 10.1016/j.jchromb.2024.124185
  • Journal Name: Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Aerospace Database, BIOSIS, CAB Abstracts, Chemical Abstracts Core, Chimica, Communication Abstracts, Compendex, Food Science & Technology Abstracts, MEDLINE, Metadex, Veterinary Science Database, Civil Engineering Abstracts
  • Keywords: Layered double hydroxide, Magnetic solid-phase extraction, Dasatinib, Erlotinib
  • Erciyes University Affiliated: Yes

Abstract

In this study, a magnetic three-dimensional nano-composite based on Rubber-Fe3O4@Ni-Co Layered double hydroxide derived from ZIF-67 template was synthesized by a hydrothermal method. The proposed nano-composite was used as a sorbent for the enrichment of trace amounts of anti-cancer drugs (dasatinib and erlotinib hydrochloride) from plasma samples followed by determination using high-performance liquid chromatographic analysis (HPLC-UV). The synthesized nano-sorbent was characterized by X-ray diffraction, field emission scanning electron microscopy, Fourier transform infrared spectroscopy, vibrating-sample magnetometer, Brunauer-Emmett-Teller surface analysis, Barrett-Joyner-Halenda pore size analysis and energy dispersive X-ray spectroscopy. Under optimal experimental conditions, factors affecting on extraction efficiency such as pH, ionic strength, extraction temperature and time, desorption solvent and time, the limit of detection (LODs) and the limit of quantification (LOQs) were obtained as 0.6, 2 µg/L for both of dasatinib and erlotinib, respectively. Also, linear range of the method were 2–500 and 2–1000 µg/L for dasatinib and erlotinib, respectively. Relative standard deviations (RSD%) for the repeatability of extraction on sorbent to sorbent were obtained as 3.59, 1.97 %, and one sorbent reusability were investigated and relative standard deviation values were obtained 5.35, 3.30 % for dasatinib and erlotinib, respectively.