Cu2O-CuO ball like/multiwalled carbon nanotube hybrid for fast and effective ultrasound-assisted solid phase extraction of uranium at ultra-trace level prior to ICP-MS detection


Aydın F., YILMAZ E., Ölmez E., SOYLAK M.

TALANTA, cilt.207, 2020 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 207
  • Basım Tarihi: 2020
  • Doi Numarası: 10.1016/j.talanta.2019.120295
  • Dergi Adı: TALANTA
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, L'Année philologique, Aerospace Database, Analytical Abstracts, Aqualine, Aquatic Science & Fisheries Abstracts (ASFA), BIOSIS, CAB Abstracts, Chimica, Communication Abstracts, Compendex, EMBASE, Food Science & Technology Abstracts, Linguistic Bibliography, MEDLINE, Metadex, Pollution Abstracts, Veterinary Science Database, Civil Engineering Abstracts
  • Anahtar Kelimeler: Uranium, Hybrid material, Hydrothermal synthesis, Multiwalled carbon nanotubes, Ultrasound-assisted solid phase extraction, ICP-MS, MAGNETIC-NANOPARTICLES, WATER SAMPLES, OXIDE NANOPARTICLES, AQUEOUS-SOLUTION, RAPID REMOVAL, ADSORPTION, SPECTROMETRY, LIQUID, U(VI), IONS
  • Erciyes Üniversitesi Adresli: Evet

Özet

Multiwalled carbon nanotube/Cu2O-CuO ball like hybrid material (MWCNTs/Cu2O-CuO) synthesized using of a green hydrothermal process was evaluated as a new sorbent for solid phase extraction of uranium with inductively coupled plasma mass spectrometry (ICP-MS). According to our best knowledge, this new material was synthesized and used as solid phase extraction adsorbent for the first time in the literature. The characterization of new hybrid material was carried out using Raman spectroscopy, X-ray diffraction (XRD) and scanning electronic microscopy techniques (SEM, SEM-EDX and SEM-Mapping). The characterization results demonstrated that the new hybrid nanostructure was successfully obtained. The ultrasound-assisted solid phase extraction (UA-SPE) procedure was performed using 100 mg of new hybrid sorbent, 1000 mu L of a 0.1% (w/v) solution of alpha-benzoin oxime and 2000 mu L of phosphate buffer at pH 7.0 for separation and preconcentration of uranium. Uranium was eluted with 2 M HCl and the levels of uranium was measured by using ICP-MS. The linearity was observed between 2.5 and 100 ng mL(-1) concentration range with a good correlation coefficient (r = 0.999, n = 7). The obtained limit of detection and quantitation values were 0.52 and 1.70 ng mL(-1) respectively. Under optimum conditions, the preconcentration factor (PF) was calculated as 13.3. The accuracy of the developed method was assessed by analyzing of TMDA-62.2, TMDA-70.2 (Environment Canada) and GBW-07423 certified reference water and soil materials. The proposed UA-SPE-ICP-MS procedure developed with MWCNTs/Cu2O-CuO hybrid material was successfully applied to the analysis of uranium at ultra-traces levels in environmental water and geological rock samples.