Electromagnetic shielding characteristics of different fabrics knitted from yarns containing stainless steel wire


Ortlek H. G., Kilic G., OKYAY G., Bilgin S.

INDUSTRIA TEXTILA, vol.62, no.6, pp.304-308, 2011 (SCI-Expanded) identifier identifier

  • Publication Type: Article / Article
  • Volume: 62 Issue: 6
  • Publication Date: 2011
  • Journal Name: INDUSTRIA TEXTILA
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.304-308
  • Erciyes University Affiliated: Yes

Abstract

In this study, the electromagnetic shielding effectiveness of various knitted structures made of Siro core-spun cotton yarns containing stainless steel wire is investigated. Electromagnetic shielding values of various knitted structures are determined by a coaxial test fixture relating to ASTM D 4935 test standards. Measurements are made in the frequency range of 30 MHz-1.73 GHz. Test results show that knitted fabrics investigated in this study have 10-20 dB shielding effectiveness for incident frequency. Also it is seen that the differences of knitted structure have an influence on the electromagnetic shielding effectiveness of fabrics.