Retrofit strategies for energy efficiency of historic urban fabric in mediterranean climate


ULU M., Arsan Z. D.

Atmosphere, cilt.11, sa.7, 2020 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 11 Sayı: 7
  • Basım Tarihi: 2020
  • Doi Numarası: 10.3390/atmos11070742
  • Dergi Adı: Atmosphere
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Agricultural & Environmental Science Database, CAB Abstracts, Compendex, Geobase, INSPEC, Veterinary Science Database, Directory of Open Access Journals
  • Erciyes Üniversitesi Adresli: Evet

Özet

© 2020 by the authors.Energy-efficient retrofitting of historic housing stock requires methodical approach, indepth analysis and case-specific regulatory system, yet only limited efforts have been realized. In large scale rehabilitation projects, it is essential to develop a retrofit strategy on how to decide energy-efficient solutions for buildings providing the most energy saving in a short time. This paper presents a pilot study conducted at a neighborhood scale, consisting of 22 pre-, early-republican and contemporary residential buildings in a historic urban fabric in the Mediterranean climate. This study aims to develop an integrated approach to describe case-specific solutions for larger scale historic urban fabric. It covers the building performance simulation (BPS) model and numerical analysis to determine the most related design parameters affecting annual energy consumption. All the case buildings were classified into three main groups to propose appropriate retrofit solutions in different impact categories. Retrofit solutions were gathered into two retrofit packages, Package 1 and 2, and separately, three individual operational solutions were determined, considering a fivelevelled assessment criteria of EN 16883:2017 Standard. Energy classes of case buildings were calculated based on National Building Energy Regulations. Changes in building classes were evaluated considering pre-and post-retrofit status of the buildings. For the integrated approach, the most related design parameters on annual energy consumption were specified through Pearson correlation analysis. The approach indicated that three buildings, representing each building group, can initially be retrofitted. For all buildings, while maximum energy saving was provided by Package 2 with 48.57%, minimum energy saving was obtained from Package 1 with 19.8%.