Determination of some metal ions by flame-AAS after their preconcentration using sodium dodecyl sulfate coated alumina modified with 2-hydroxy-(3-((1-H-indol 3-yle)phenyl) methyl) 1-H-indol (2-HIYPMI)


JAMSHIDI M., Ghaedi M., Mortazavi K., Biareh M. N., SOYLAK M.

FOOD AND CHEMICAL TOXICOLOGY, cilt.49, sa.6, ss.1229-1234, 2011 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 49 Sayı: 6
  • Basım Tarihi: 2011
  • Doi Numarası: 10.1016/j.fct.2011.02.025
  • Dergi Adı: FOOD AND CHEMICAL TOXICOLOGY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1229-1234
  • Anahtar Kelimeler: Sodium dodecyl sulfate coated alumina (SDS-A), Atomic absorption spectrometry, Solid phase extraction, 2-hydroxy-(3-((1-H-indol 3-yle)phenyl) methyl) 1-H-indol (2-HIYPMI), SOLID-PHASE EXTRACTION, ATOMIC-ABSORPTION-SPECTROMETRY, AMBERLITE XAD-4 RESIN, WATER SAMPLES, TRACE AMOUNTS, SCHIFF-BASE, ONLINE PRECONCENTRATION, DIFFERENT MATRICES, HEAVY-METALS, SEPARATION
  • Erciyes Üniversitesi Adresli: Evet

Özet

Selective, sensitive and efficient methods for preconcentration of trace amounts of metal ions including Cr(3+), Cu(2+)., Zn(2+) and Ni(2+) ions by incorporation of 2-hydroxy-(3-((1-H-indol 3-yle)phenyl) methyl) 1-H-indol (2-HIYPMI) on SDS-A has been reported. The proposed methods are based on the uptake of chelate of under study metal ions with these new ligands loaded on SDS-A. The influences of the analytical parameters including pH, ligand and SDS amount, eluting solution (type and concentrations) and sample volume on metal ions recoveries were investigated. The extraction efficiency was >95% with relative standard deviation lower than 5%. The method has been successfully applied for the extraction and determination of these ions content in some real samples. (C) 2011 Elsevier Ltd. All rights reserved.