Effects of different resin sealing therapies on nanoleakage within artificial non-cavitated enamel lesions


Creative Commons License

ARSLAN S., Lipski L., Dubbs K., Elmalı F., Ozer F.

DENTAL MATERIALS JOURNAL, cilt.37, sa.6, ss.981-987, 2018 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 37 Sayı: 6
  • Basım Tarihi: 2018
  • Doi Numarası: 10.4012/dmj.2017-027
  • Dergi Adı: DENTAL MATERIALS JOURNAL
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.981-987
  • Erciyes Üniversitesi Adresli: Evet

Özet

The aim of this study was to evaluate nanoleakage within the different lesion-sealing therapies applied to artificial non-cavitated enamel lesions. Thirty-two human anterior teeth were used. Artificial subsurface enamel lesions were produced on the labial surfaces of teeth. The specimens were then randomly divided into three groups (n=10): Group I- Clinpro Sealant application; Group II- ExciTE F adhesive resin application; and Group III- ICON resin infiltrant application. Each group was further divided into two subgroups: control and thermocycler. Nanoleakage was calculated by the digital image analysis software. In the control and thermocycled groups, there was no statistically significant difference between the Groups I, II, and III (p>0.05). The only significant leakage scores were obtained between the Group III control and thermocycler groups (p=0.027). ICON infiltrant can be used as an alternative to dental adhesives and fissure sealants in the sealing of initial non-cavitated enamel lesions. But the resin may become more affected by the water sorption than other resin materials over time. More studies are needed to evaluate long-term durability of resin infiltrants.