Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?


Çetinkaya Z., ELÇİK D., KELEŞOĞLU Ş., Cesur B., Yaşan M., Karabiyik U., ...Daha Fazla

Turkish Journal of Medical Sciences, cilt.53, sa.6, ss.1799-1806, 2023 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 53 Sayı: 6
  • Basım Tarihi: 2023
  • Doi Numarası: 10.55730/1300-0144.5750
  • Dergi Adı: Turkish Journal of Medical Sciences
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, CAB Abstracts, MEDLINE, Veterinary Science Database, TR DİZİN (ULAKBİM)
  • Sayfa Sayıları: ss.1799-1806
  • Anahtar Kelimeler: atrial-his interval, AV block, bundle branch block, Transcatheter aortic valve implantation
  • Erciyes Üniversitesi Adresli: Evet

Özet

Background/aim: Despite advancements in valve technology and increased clinical experience, complications related to conduction defects after transcatheter aortic valve implantation (TAVR) have not improved as rapidly as expected. In this study, we aimed to predict the development of complete atrioventricular (AV) block and bundle branch block during and after the TAVR procedure and to investigate any changes in the cardiac conduction system before and after the procedure using electrophysiological study. Materials and methods: A total of 30 patients who were scheduled for TAVR at our cardiovascular council were planned to be included in the study. TAVR was performed on patients at Erciyes University Medical Faculty Hospital as a single center between May 2019 and August 2020 Diagnostic electrophysiological study was performed before the TAVR procedure and after its completion. Changes in the cardiac conduction system during the preprocedure, intra-procedure, and postprocedure periods were recorded. Results: Significant increases in baseline cycle length, atrial-His (AH) interval, his-ventricular (HV) interval and atrioventricular (AV) distance were observed before and after the TAVR procedure (p = 0.039, p < 0.001, p = 0.018, p < 0.001, respectively). During the TAVR procedure, the preprocedural HV interval was longer in patients who developed AV block and bundle branch block compared to those who did not and this difference was statistically significant (p = 0.024). ROC curve analysis revealed that a TAVR preprocedure HV value >59.5 ms had 86% specificity and 75% sensitivity in detecting AV block and bundle branch block (AUC = 0.83, 95% CI: 0.664–0.996, p = 0.013). The preprocedure HV distance was 98 ± 10.55ms in the group with permanent pacemaker implantation and the mean value in the group without permanent pacemaker implantation was 66.27 ± 15.55 ms, showing a borderline significant difference (p = 0.049). Conclusion: The prolongation of HV interval in patients with AV block and bundle branch block suggests that the block predominantly occurs at the infra-hisian level. Patients with longer preprocedural HV intervals should be closely monitored for the need for permanent pacemaker implantation after the TAVR procedure.