CaFeMo layered triple hydroxide-based sensor for sensitive electrochemical detection of caffeic acid in food samples
Microchemical Journal, cilt.231, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 231
- Basım Tarihi: 2026
- Doi Numarası: 10.1016/j.microc.2026.120140
- Dergi Adı: Microchemical Journal
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, BIOSIS, Chemical Abstracts Core, Chimica, Index Islamicus, Academic Search Ultimate (EBSCO), Engineering Source (EBSCO)
- Anahtar Kelimeler: Caffeic acid, Differential pulse voltammetry, Layered triple hydroxide, Red wine, Tea
- Erciyes Üniversitesi Adresli: Evet
Özet
Caffeic acid (CA) exhibits antibacterial, antiviral, and anticancer properties; however, excessive intake may lead to genotoxic effects. Therefore, the development of an efficient electrochemical sensor for the sensitive and reliable detection of CA is of great importance. In this work, calcium–iron–molybdenum layered triple hydroxide modified screen-printed carbon electrode (CaFeMo-LTH/SPCE) was developed as an efficient electrochemical sensing platform for the sensitive detection of CA in beverage samples. The main advantage of this work is the use of a trimetallic hydroxide structure, where Ca improves structural stability, Fe provides redox-active sites, and Mo enhances catalytic activity. This combined effect creates a porous, hydroxyl-rich, and highly active electrode surface that improves CA adsorption, electron transfer, and signal response. The successful formation of CaFeMo-LTH was confirmed by FTIR, XRD, FE-SEM, EDX, elemental mapping, and TGA, showing a crystalline, thermally stable, and well-integrated layered structure. Electrochemical studies showed that the CaFeMo-LTH modification increased the electroactive surface area, reduced charge-transfer resistance, and improved the oxidation response of CA compared with the bare SPCE. Under optimized conditions using 0.1 M phosphate buffer solution at pH 7.0, the CaFeMo-LTH/SPCE sensor showed a wide linear detection range from 0.002 to 100 μM, with a very low limit of detection of 5 nM and limit of quantification of 15.45 nM and excellent sensitivity 2.82 μA μM−1 cm−2 showing good sensing performance toward CA detection from food samples. The sensor also showed good selectivity against common interfering species, along with acceptable repeatability and reproducibility. The practical value of the sensor was confirmed by real sample analysis with satisfactory recoveries from 95.7 to 104.9%. These results show that the CaFeMo-LTH/SPCE is a low-cost, sensitive, stable, and reliable sensing platform for monitoring CA in complex food matrices.