Design parameter investigation of industrial size ultrasound textile treatment bath


Perinçek S., Uzgur E., Duran K., Doğan A., Körlü A., BAHTİYARİ M. I.

ULTRASONICS SONOCHEMISTRY, cilt.16, sa.1, ss.184-189, 2009 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 16 Sayı: 1
  • Basım Tarihi: 2009
  • Doi Numarası: 10.1016/j.ultsonch.2008.06.003
  • Dergi Adı: ULTRASONICS SONOCHEMISTRY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.184-189
  • Anahtar Kelimeler: Textile treatment, Ultrasound, Finite element analysis, POWER ULTRASOUND, DYES
  • Erciyes Üniversitesi Adresli: Hayır

Özet

Design requirements for industrial size ultrasound bath for textile treatments have been determined. For this purpose, effects of sound pressure level, bath temperature, bath volume, textile material type and hydrophility degree of fabric were examined extensively. Finite element analysis (FEA) was used to investigate spacing and alignment of the ultrasound source transducers to reach effective and homogenous acoustic pressure distribution in the bath. It was found that textile material type, bath temperature and volume led to significant changes at sound pressure level. These parameters should be taken into consideration in designing of industrial size ultrasound bath for textile treatments. Besides, wettability of textiles is highly dependent to the distance from the transducers. (C) 2008 Elsevier B.V. All rights reserved.