Effect of Photobiomodulation Therapy on Peri-Implant Bone Healing in Extra-Short Implants in a Rabbit Model: A Pilot Study.


Kuzu T. E., Öztürk K., Gürgan C. A., Üşümez A., Yay A. H., Göktepe Ö.

Photobiomodulation, photomedicine, and laser surgery, cilt.40, sa.6, ss.402-409, 2022 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 40 Sayı: 6
  • Basım Tarihi: 2022
  • Doi Numarası: 10.1089/photob.2021.0098
  • Dergi Adı: Photobiomodulation, photomedicine, and laser surgery
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.402-409
  • Anahtar Kelimeler: PBMT, dental implant, short implant, bone-implant contact, LOW-LEVEL LASER, SHORT DENTAL IMPLANTS, RESONANCE FREQUENCY, MAMMALIAN-CELLS, OSSEOINTEGRATION, STABILITY, REGENERATION, PHOTOTHERAPY, IRRADIATION, EXPRESSION
  • Erciyes Üniversitesi Adresli: Evet

Özet

Objective: To evaluate the effects of photobiomodulation therapy (PBMT) at distinct energy levels on peri-implant bone healing in extra-short implants in a experimental rabbit model.Background: The effect of PBMT on peri-implant bone healing in short implants remains unclear. This explored the effect of PBMT on extra-short implants in terms of bone-implant contact (BIC) length and rate, and implant stability quotient (ISQ).Methods: Fifteen white New Zealand rabbits were randomly divided into five groups. In all groups, extra-short implants (3.5 x 4 mm; Nucleoss T6, Izmir/Turkey) were placed in both tibias of the rabbits. PBMT was performed in four groups (group 1, 5 J/cm(2); group 2, 10 J/cm(2); group 3, 20 J/cm(2); and group 4, 25 J/cm(2)); no PBMT was performed in the control group. On the 30th day, the rabbits were sacrificed and peri-implant tissue samples were obtained to determine the BIC length and BIC rate. Implant stability levels were measured by resonance frequency analysis using the Osstell penguin device and were determined as ISQ values on the 1st and 30th days of the study.Results: PBMT significantly increased the BIC length and BIC rate in groups 3 and 4 (p < 0.001). For the ISQ values, there were significant differences between the 1st and 30th day (p < 0.001). On the 30th day, the ISQ values were significantly higher in groups 3 and 4 compared with the remaining groups (p < 0.001).Conclusions: In this study, PBMT improved peri-implant bone healing through increase in BIC length, BIC rate, and ISQ parameter values in extra-short implants.