EFFECTS OF DROPLET COMPOSITION ON NANODROPLET-MEDIATED HISTOTRIPSY


VLAİSAVLJEVİCH E., Aydin O., Durmaz Y. Y., LİN K., FOWLKES B., XU Z., ...Daha Fazla

ULTRASOUND IN MEDICINE AND BIOLOGY, cilt.42, sa.4, ss.931-946, 2016 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 42 Sayı: 4
  • Basım Tarihi: 2016
  • Doi Numarası: 10.1016/j.ultrasmedbio.2015.11.027
  • Dergi Adı: ULTRASOUND IN MEDICINE AND BIOLOGY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.931-946
  • Anahtar Kelimeler: Nanodroplet, Histotripsy, Perfluoropentane, Perfluorohexane, Cavitation, PULSED CAVITATIONAL ULTRASOUND, THERAPEUTIC ULTRASOUND, TISSUE STIFFNESS, CELL ABLATION, IN-VIVO, FREQUENCY, MODEL, THRESHOLDS, EROSION
  • Erciyes Üniversitesi Adresli: Hayır

Özet

Nanodroplet-mediated histotripsy (NMH) is a targeted ablation technique combining histotripsy with nanodroplets that can be selectively delivered to tumor cells. In two previous studies, polymer-encapsulated perfluoropentane nanodroplets were used to generate well-defined ablation similar to that obtained with histotripsy, but at significantly lower pressure, whenNMHtherapy was applied at a pulse repetition frequency (PRF) of 10 Hz. However, cavitation was not maintained over multiple pulses when ultrasound was applied at a lower PRF (i.e., 1-5 Hz). We hypothesized that nanodroplets with a higher-boiling-point perfluorocarbon core would provide sustainable cavitation nuclei, allowing cavitation to be maintained over multiple pulses, even at low PRF, which is needed for efficient and complete tissue fractionation via histotripsy. To test this hypothesis, we investigated the effects of droplet composition on NMH therapy by applying histotripsy at various frequencies (345 kHz, 500 kHz, 1.5 MHz, 3 MHz) to tissue phantoms containing perfluoropentane (PFP, boiling point similar to 29 degrees C, surface tension similar to 9.5 mN/m) and perfluorohexane (PFH, boiling point similar to 56 degrees C, surface tension similar to 11.9 mN/m) nanodroplets. First, the effects of droplet composition on the NMH cavitation threshold were investigated, with results revealing a significant decrease (>10 MPa) in the peak negative pressure (p-) cavitation threshold for both types of nanodroplets compared with controls. A slight decrease (similar to 1-3 MPa) in threshold was observed for PFP phantoms compared with PFH phantoms. Next, the ability of nanodroplets to function as sustainable cavitation nuclei over multiple pulses was investigated, with results revealing that PFH nanodroplets were sustainable cavitation nuclei over 1,000 pulses, whereas PFP nanodroplets were destroyed during the first few pulses (<50 pulses), likely because of the lower boiling point. Finally, tissue phantoms containing a layer of embedded red blood cells were used to compare the damage generated for NMH treatments using PFP and PFH droplets, with results indicating that PFH nanodroplets significantly improved NMH ablation, allowing for well-defined lesions to be generated at all frequencies and PRFs tested. Overall, the results of this study provide significant insight into the role of droplet composition in NMH therapy and provide a rational basis to tailor droplet parameters to improve NMH tissue fractionation. (E-mail: melsayed@umich.edu or http://www.bme.umich.edu/centlab.php) (C) 2016World Federation for Ultrasound in Medicine & Biology.