Sequential coprecipitation and matrix removal for determination of cadmium impurities from multivitamin supplements by inductively coupled plasma mass spectrometry and method validation by isotope dilution analysis of SRM 3280 multivitamin/multielement tablets


Creative Commons License

White J., Celik A., Washington R., Yilmaz V., Mitchum T., Arslan Z.

MICROCHEMICAL JOURNAL, cilt.139, ss.242-249, 2018 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 139
  • Basım Tarihi: 2018
  • Doi Numarası: 10.1016/j.microc.2018.03.010
  • Dergi Adı: MICROCHEMICAL JOURNAL
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.242-249
  • Anahtar Kelimeler: Cadmium, Multivitamin/mineral supplement, Coprecipitation, Hydrofluoric acid, Triethylamine, ICP-MS, DIETARY-SUPPLEMENTS, ELEMENTS, LEAD, COMPLEXES, CALCIUM, MERCURY, METALS
  • Erciyes Üniversitesi Adresli: Evet

Özet

In this paper, we examined three different sequential coprecipitation schemes based on Mg(OH)(2) and CaF2 precipitation using triethylamine (TEA) and hydrofluoric acid (HF), respectively, for determination of cadmium (Cd) impurities from multivitamin/mineral (MVM) supplements by isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS). The schemes involved three-step coprecipitation with either TEA alone or in combination with HF and are designated as Scheme 1 (TEA-TEA-TEA), Scheme 2 (TEA-HF-TEA) and Scheme 3 (HF-TEA-TEA) according to the addition sequence of each reagent. Experiments were carried out with MVM solutions spiked with 60 mu g L-1 Cd from a multielement standard solution. All schemes provided quantitative separation of Cd from MVM matrix. Scheme I was the least effective in removal of interfering concomitant elements, molybdenum (Mo) and tin (Sn). Scheme 2 performed better for Sn, but failed in eliminating Mo. Scheme 3 was the most effective in eliminating both Mo and Sn. Mo levels in test MVM solutions reduced from 4.314 mu g mL(-1) to as low as 0.014 mu g mL(-1) while that for Sn decreased from 0.5 mu g mL(-1) to 0.018 mu g mL(-1) allowing interference-free determination of Cd to be achieved. Salt-matrix due to Mg, Ca, P and K along with the essential elements (Mn, Fe, Cu and Zn) levels was also reduced significantly. Reagent blanks from HF and TEA were insignificant (0.008 mu g mL(-1)) allowing a limit of detection of 0.004 mu g mL(-1) or 0.26 ng g(-1) Cd to be achieved (3 sigma; n = 6). The performance of the coprecipitation method (Scheme 3) was validated by determination of Cd in multivitamin/multielement tablets certified reference material (SRM 3280) by ID-ICP-MS. Experimental results (ng g(-1)) and recoveries were 78.8 +/- 4.7 (98.5%), 77.9 +/- 5.2 (97.4%) and 76.5 +/- 4.8 (95.6%) for Cd-110, Cd-111 and Cd-114 isotopes, respectively. Several commercial MVM supplements were analyzed using the method. Mean Cd concentration ranged from 21.4 ng g(-1) to 93.3 ng g(-1). These values are much lower than those reported to date for various MVM supplements by ICP-MS determinations without chemical separation. (C) 2018 Elsevier B.V. All rights reserved.